How to drain fire sprinkler system

Given that the entire system needs to be draine the amount of water will vary based on the size of the system. To drain a wet pipe system properly, the following steps should be followed: Close all sprinkler control valves. When control valves are close it should be ascertained whether the fire department connection is on the system side or supply side of the valve.


In a fire sprinkler system there can be multiple drains. But does it also apply to single-valve auxiliary drains serving regions. Maintenance on a Dry Pipe Fire Sprinkler System is a minimum of Two .

The main drain of an automatic sprinkler system is actually the water flow control valve. Control Valves and Drains Introduction. Typical fire sprinkler system in a commercial building. Automatic sprinklers are the most reliable and effective . This video will show you how to drain a fire sprinkler system. Good knowledge for training or just an emergency.


RCW Dry System Valve - Operation Animation - Duration: 1:40. Globe Fire Sprinkler Corporation 662.

How to drain a drumdrip low point. Coast Regional Manager, National Fire Sprinkler Association and to each of. Drain Fire Sprinkler System Low Points. The fire sprinkler system connects to the water main.


In Illinois the water flows through a Backflow Valve. The most common purpose of drainage is to remove water from a water-based fire suppression system , such as a fire sprinkler or a fire standpipe system. If the system is properly pitche the water will drain back to the riser and defined . Auxiliary, or low point, drains are required in sprinkler systems where pipe is installed.


In these dry systems, when a fire occurs a “Dry Pipe Valve” operates and allows. To facilitate draining water out of dry sprinkler systems , most of these systems. Unlike a wet pipe system , dry sprinklers are free of water until a fire is.


And even if you completely drain the system , there is still humidity in . This is the main drain valve on the right, and the flow switch on the left (red box). This procedure identifies how to conduct a sprinkler system main drain test. Discharge of AFS water to a storm drain system is conditionally exempt from regulation under the . STEP 1: Determine if A Fire Sprinkler System is required for your building.


Fire sprinkler systems automatically detect and then control, suppress,. Every automatic fire sprinkler system has one or more control valves.

Durably identify your sprinkler systems , sprinkler valves and other fire protection. Also included in this package is information about how your sprinkler system works to. In order to ensure that the pump is working, open the drain.


When properly installed and maintaine automatic fire sprinkler systems have proven to be the. The automatic drain valve is in place and operating properly. NFPA serves as the primary automatic fire sprinkler system design and. Figure 1: This photo shows a 4-in. If the temperature in the area where your fire sprinkler system is located.


We highly recommend that you have a main drain flow test. Why is the maintenance and testing of fire sprinkler systems so crucial to fire. VFP can provide you with a dry pipe fire sprinkler system based on your fire sprinkler requirements.